Alastair Martin, PhD

Professor
MSBI Program Director
Associate Chair, Capital Projects
Adjunct Professor

Biography

Alastair J. Martin, PhD, is the Program Director for the Master of Science in Biomedical Imaging (MSBI) graduate program and Associate Chair for Capital Projects in the Department of Radiology and Biomedical Imaging at the University of California, San Francisco. Dr. Martin obtained his BSc in Physics from the University of British Columbia, Canada, in 1987, and he earned his MSc in Medical Biophysics from the University of Toronto, Canada in 1989. He completed his PhD in Medical Physics from the University of Toronto in 1994, followed by a postdoctoral fellowship in Medical Biophysics from the University of Western Ontario, Canada, in 1996.

Dr. Martin’s research is focused on applications where MR methods enhance the delivery of therapy. His research specifically targets neurosurgical and endovascular applications where MR techniques may provide significant benefits. These activities include basic science developments, animal studies, and clinical research. Dr. Martin primarily focuses his research on the development of MR guidance techniques for delivering deep brain stimulator electrodes to precise locations inside the brain. Another interest of Dr. Martin’s is the application of MR methods of endovascular procedures where he investigates safety concerns with endovascular devices within an MR system, and presently, he is contributing to the exploration of deflectable catheters.

Dr. Martin provides his services to many journals as a peer-reviewer. He has published over 100 journal articles, over 200 conference abstracts and 10 book chapters.

Expertise:
Interventional magnetic resonance imaging

Specialty:
MR in endovascular techniques, revascularizations, embolization, image-guided, minimally invasive neurosurgical techniques

Professional Interests:
Interventional MR, endovascular MR, MR fluoroscopy, vascular imaging, perfusion, diffusion, Parkinson's disease, deep brain stimulation, convection enhanced delivery

Education and Training:
• Bachelor of Science: University of British Columbia, Canada - Physics
• Masters of Science: University of Toronto, Canada - Medical Biophysics
• Doctor of Philosophy: University of Toronto, Canada - Medical Biophysics
• Postdoctoral Fellowship: University of Western Ontario, Canada - Medical Biophysics

Education

PhD, 1994 - Medical Biophysics, University of Toronto
MSc, 1989 - Medical Biophysics, University of Toronto
BSc (Honours), 1987 - Physics, University of British Columbia

Honors and Awards

Fellowship, Heart and Stroke Foundation of Canada, 1995-1996
Graduate Scholarship, Natural Sciences and Engineering Research Council (Canada), 1990-1992
Robert Pudenz Award, Congress of Neurological Surgeons, 1989
Graduate Scholarship, Natural Sciences and Engineering Research Council (Canada), 1987-1989

Publications

Woolen SA, Becker AE, Martin AJ, Knoerl R, Lam V, Folsom J, Eusemann C, Hess CP, Deshpande V. Erratum for: Ecodesign and Operational Strategies to Reduce the Carbon Footprint of MRI for Energy Cost Savings. Radiology. 2023 Jul; 308(1):e239020.
Woolen SA, Becker AE, Martin AJ, Knoerl R, Lam V, Folsom J, Eusemann C, Hess CP, Deshpande V. Ecodesign and Operational Strategies to Reduce the Carbon Footprint of MRI for Energy Cost Savings. Radiology. 2023 05; 307(4):e230441.
Woolen SA, Kim CJ, Hernandez AM, Becker A, Martin AJ, Kuoy E, Pevec WC, Tutton S. Radiology Environmental Impact: What Is Known and How Can We Improve? Acad Radiol. 2023 04; 30(4):625-630.
Kilbride BF, Narsinh KH, Jordan CD, Mueller K, Moore T, Martin AJ, Wilson MW, Hetts SW. MRI-guided endovascular intervention: current methods and future potential. Expert Rev Med Devices. 2022 Oct; 19(10):763-778.
Lee AT, Han KJ, Nichols N, Sudhakar VR, Burke JF, Wozny TA, Chung JE, Volz MM, Ostrem JL, Martin AJ, Larson PS, Starr PA, Wang DD. Targeting Accuracy and Clinical Outcomes of Awake versus Asleep Interventional Magnetic Resonance Imaging-Guided Deep Brain Stimulation for Parkinson's Disease: The University of California, San Francisco Experience. Neurosurgery. 2022 11 01; 91(5):717-725.
Yuh EL, Jain S, Sun X, Pisica D, Harris MH, Taylor SR, Markowitz AJ, Mukherjee P, Verheyden J, Giacino JT, Levin HS, McCrea M, Stein MB, Temkin NR, Diaz-Arrastia R, Robertson CS, Lingsma HF, Okonkwo DO, Maas AIR, Manley GT, TRACK-TBI Investigators for the CENTER-TBI Investigators, Adeoye O, Badjatia N, Boase K, Bodien Y, Corrigan JD, Crawford K, Dikmen S, Duhaime AC, Ellenbogen R, Feeser VR, Ferguson AR, Foreman B, Gardner R, Gaudette E, Gonzalez L, Gopinath S, Gullapalli R, Hemphill JC, Hotz G, Keene CD, Kramer J, Kreitzer N, Lindsell C, Machamer J, Madden C, Martin A, McAllister T, Merchant R, Nelson L, Ngwenya LB, Noel F, Nolan A, Palacios E, Perl D, Rabinowitz M, Rosand J, Sander A, Satris G, Schnyer D, Seabury S, Toga A, Valadka A, Vassar M, Zafonte R. Pathological Computed Tomography Features Associated With Adverse Outcomes After Mild Traumatic Brain Injury: A TRACK-TBI Study With External Validation in CENTER-TBI. JAMA Neurol. 2021 09 01; 78(9):1137-1148.
Liu X, Kao E, Haraldsson H, Ballweber M, Martin A, Li Y, Wang Y, Saloner D. Identification of intra-individual variation in intracranial arterial flow by MRI and the effect on computed hemodynamic descriptors. MAGMA. 2021 Oct; 34(5):659-666.
Luo M, Narasimhan S, Larson PS, Martin AJ, Konrad PE, Miga MI. Impact of brain shift on neural pathways in deep brain stimulation: a preliminary analysis via multi-physics finite element models. J Neural Eng. 2021 04 06; 18(5).
Morrison MA, Lee AT, Martin AJ, Dietiker C, Brown EG, Wang DD. DBS targeting for essential tremor using intersectional dentato-rubro-thalamic tractography and direct proton density visualization of the VIM: technical note on 2 cases. J Neurosurg. 2021 Jan 15; 135(3):806-814.
Boutet A, Chow CT, Narang K, Elias GJB, Neudorfer C, Germann J, Ranjan M, Loh A, Martin AJ, Kucharczyk W, Steele CJ, Hancu I, Rezai AR, Lozano AM. Improving Safety of MRI in Patients with Deep Brain Stimulation Devices. Radiology. 2020 08; 296(2):250-262.
Luo M, Larson PS, Martin AJ, Miga MI. Accounting for Deformation in Deep Brain Stimulation Surgery With Models: Comparison to Interventional Magnetic Resonance Imaging. IEEE Trans Biomed Eng. 2020 10; 67(10):2934-2944.
Martin AJ. MRI in Patients with Deep Brain Stimulation Electrodes: Balancing Risks and Benefits. Radiology. 2019 Oct; 293(1):184-185.
Jordan CD, Thorne BRH, Wadhwa A, Losey AD, Ozhinsky E, Kondapavulur S, Fratello V, Moore T, Stillson C, Yee C, Watkins RD, Scott GC, Martin AJ, Zhang X, Wilson MW, Hetts SW. Wireless Resonant Circuits Printed Using Aerosol Jet Deposition for MRI Catheter Tracking. IEEE Trans Biomed Eng. 2020 03; 67(3):876-882.
Christine CW, Bankiewicz KS, Van Laar AD, Richardson RM, Ravina B, Kells AP, Boot B, Martin AJ, Nutt J, Thompson ME, Larson PS. Magnetic resonance imaging-guided phase 1 trial of putaminal AADC gene therapy for Parkinson's disease. Ann Neurol. 2019 05; 85(5):704-714.
Golestanirad L, Kirsch J, Bonmassar G, Downs S, Elahi B, Martin A, Iacono MI, Angelone LM, Keil B, Wald LL, Pilitsis J. RF-induced heating in tissue near bilateral DBS implants during MRI at 1.5 T and 3T: The role of surgical lead management. Neuroimage. 2019 01 01; 184:566-576.
Jordan CD, Han M, Kondapavulur S, Vera DB, Neumann KD, Moore T, Stillson C, Krug R, Behr S, Seo Y, VanBrocklin HF, Larson PEZ, Wilson M, Martin AJ, Hetts SW. Quantification of 89 Zr-Iron oxide nanoparticle biodistribution using PET-MR and ultrashort TE sequences. J Magn Reson Imaging. 2018 12; 48(6):1717-1720.
Kundishora AJ, Englot DJ, Starr PA, Martin AJ, Larson PS. Venous Thromboembolism during Interventional MRI-Guided Stereotactic Surgery. Stereotact Funct Neurosurg. 2018; 96(1):40-45.
Larson PS, Starr PA, Martin AJ. Deep Brain Stimulation: Interventional and Intraoperative MRI Approaches. Prog Neurol Surg. 2018; 33:187-197.
Yang JK, Cote AM, Jordan CD, Kondapavulur S, Losey AD, McCoy D, Chu A, Yu JF, Moore T, Stillson C, Settecase F, Alexander MD, Nicholson A, Cooke DL, Saeed M, Barry D, Martin AJ, Wilson MW, Hetts SW. Interventional magnetic resonance imaging guided carotid embolectomy using a novel resonant marker catheter: demonstration of preclinical feasibility. Biomed Microdevices. 2017 Sep 25; 19(4):88.
Martin AJ, Starr PA, Ostrem JL, Larson PS. Hemorrhage Detection and Incidence during Magnetic Resonance-Guided Deep Brain Stimulator Implantations. Stereotact Funct Neurosurg. 2017; 95(5):307-314.
Zhang X, Martin A, Jordan C, Lillaney P, Losey A, Pang Y, Hu J, Wilson M, Cooke D, Hetts SW. Design of catheter radio frequency coils using coaxial transmission line resonators for interventional neurovascular MR imaging. Quant Imaging Med Surg. 2017 Apr; 7(2):187-194.
Lum MA, Martin AJ, Alexander MD, McCoy DB, Cooke DL, Lillaney P, Moftakhar P, Amans MR, Settecase F, Nicholson A, Dowd CF, Halbach VV, Higashida RT, McDermott MW, Saloner D, Hetts SW. Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging. PLoS One. 2016; 11(11):e0163554.
Southwell DG, Narvid JA, Martin AJ, Qasim SE, Starr PA, Larson PS. Comparison of Deep Brain Stimulation Lead Targeting Accuracy and Procedure Duration between 1.5- and 3-Tesla Interventional Magnetic Resonance Imaging Systems: An Initial 12-Month Experience. Stereotact Funct Neurosurg. 2016; 94(2):102-7.
Lillaney PV, Yang JK, Losey AD, Martin AJ, Cooke DL, Thorne BR, Barry DC, Chu A, Stillson C, Do L, Arenson RL, Saeed M, Wilson MW, Hetts SW. Endovascular MR-guided Renal Embolization by Using a Magnetically Assisted Remote-controlled Catheter System. Radiology. 2016 10; 281(1):219-28.
Martin AJ, Larson PS, Ziman N, Levesque N, Volz M, Ostrem JL, Starr PA. Deep brain stimulator implantation in a diagnostic MRI suite: infection history over a 10-year period. J Neurosurg. 2017 Jan; 126(1):108-113.
San Luciano M, Katz M, Ostrem J, Martin A, Starr P, Ziman N, Larson P. Effective Interventional Magnetic Resonance Image-Guided Laser Ablations in a Parkinson's Disease Patient with Refractory Tremor. Mov Disord Clin Pract. 2016 May-Jun; 3(3):312-314.
Ostrem JL, Ziman N, Galifianakis NB, Starr PA, Luciano MS, Katz M, Racine CA, Martin AJ, Markun LC, Larson PS. Clinical outcomes using ClearPoint interventional MRI for deep brain stimulation lead placement in Parkinson's disease. J Neurosurg. 2016 Apr; 124(4):908-16.
Settecase F, Martin AJ, Lillaney P, Losey A, Hetts SW. Magnetic Resonance-Guided Passive Catheter Tracking for Endovascular Therapy. Magn Reson Imaging Clin N Am. 2015 Nov; 23(4):591-605.
Genet M, Chuan Lee L, Ge L, Acevedo-Bolton G, Jeung N, Martin A, Cambronero N, Boyle A, Yeghiazarians Y, Kozerke S, Guccione JM. A Novel Method for Quantifying Smooth Regional Variations in Myocardial Contractility Within an Infarcted Human Left Ventricle Based on Delay-Enhanced Magnetic Resonance Imaging. J Biomech Eng. 2015 Aug; 137(8):081009.
Moftakhar P, Lillaney P, Losey AD, Cooke DL, Martin AJ, Thorne BR, Arenson RL, Saeed M, Wilson MW, Hetts SW. New-Generation Laser-lithographed Dual-Axis Magnetically Assisted Remote-controlled Endovascular Catheter for Interventional MR Imaging: In Vitro Multiplanar Navigation at 1.5 T and 3 T versus X-ray Fluoroscopy. Radiology. 2015 Dec; 277(3):842-52.
Tanaka Y, Genet M, Chuan Lee L, Martin AJ, Sievers R, Gerstenfeld EP. Utility of high-resolution electroanatomic mapping of the left ventricle using a multispline basket catheter in a swine model of chronic myocardial infarction. Heart Rhythm. 2015 Jan; 12(1):144-54.
Silvestrini MT, Yin D, Martin AJ, Coppes VG, Mann P, Larson PS, Starr PA, Zeng X, Gupta N, Panter SS, Desai TA, Lim DA. Interventional magnetic resonance imaging-guided cell transplantation into the brain with radially branched deployment. Mol Ther. 2015 Jan; 23(1):119-29.
Starr PA, Markun LC, Larson PS, Volz MM, Martin AJ, Ostrem JL. Interventional MRI-guided deep brain stimulation in pediatric dystonia: first experience with the ClearPoint system. J Neurosurg Pediatr. 2014 Oct; 14(4):400-8.
Martin AJ, Lillaney P, Saeed M, Losey AD, Settecase F, Evans L, Arenson RL, Wilson MW, Hetts SW. Digital subtraction MR angiography roadmapping for magnetic steerable catheter tracking. J Magn Reson Imaging. 2015 Apr; 41(4):1157-62.
Ivan ME, Yarlagadda J, Saxena AP, Martin AJ, Starr PA, Sootsman WK, Larson PS. Brain shift during bur hole-based procedures using interventional MRI. J Neurosurg. 2014 Jul; 121(1):149-60.
Losey AD, Lillaney P, Martin AJ, Cooke DL, Wilson MW, Thorne BR, Sincic RS, Arenson RL, Saeed M, Hetts SW. Magnetically assisted remote-controlled endovascular catheter for interventional MR imaging: in vitro navigation at 1.5 T versus X-ray fluoroscopy. Radiology. 2014 Jun; 271(3):862-9.
Lillaney P, Caton C, Martin AJ, Losey AD, Evans L, Saeed M, Cooke DL, Wilson MW, Hetts SW. Comparing deflection measurements of a magnetically steerable catheter using optical imaging and MRI. Med Phys. 2014 Feb; 41(2):022305.
Sincic RS, Caton CJ, Lillaney P, Goodfriend S, Ni J, Martin AJ, Losey AD, Shah N, Yee EJ, Evans L, Malba V, Bernhardt AF, Settecase F, Cooke DL, Saeed M, Wilson MW, Hetts SW. System architecture for a magnetically guided endovascular microcatheter. Biomed Microdevices. 2014 Feb; 16(1):97-106.
Wilson MW, Martin AB, Lillaney P, Losey AD, Yee EJ, Bernhardt A, Malba V, Evans L, Sincic R, Saeed M, Arenson RL, Hetts SW. Magnetic catheter manipulation in the interventional MR imaging environment. J Vasc Interv Radiol. 2013 Jun; 24(6):885-91.
Losey AD, Lillaney P, Martin AJ, Halbach VV, Cooke DL, Dowd CF, Higashida RT, Saloner DA, Wilson MW, Saeed M, Hetts SW. Safety of retained microcatheters: an evaluation of radiofrequency heating in endovascular microcatheters with nitinol, tungsten, and polyetheretherketone braiding at 1.5 T and 3 T. J Neurointerv Surg. 2014 May; 6(4):314-9.
Hetts SW, Saeed M, Martin A, Lillaney P, Losey A, Yee EJ, Sincic R, Do L, Evans L, Malba V, Bernhardt AF, Wilson MW, Patel A, Arenson RL, Caton C, Cooke DL. Magnetically-Assisted Remote Controlled Microcatheter Tip Deflection under Magnetic Resonance Imaging. J Vis Exp. 2013 Apr 04; (74).
Rosenbluth KH, Martin AJ, Mittermeyer S, Eschermann J, Dickinson PJ, Bankiewicz KS. Rapid inverse planning for pressure-driven drug infusions in the brain. PLoS One. 2013; 8(2):e56397.
Silvestrini MT, Yin D, Coppes VG, Mann P, Martin AJ, Larson PS, Starr PA, Gupta N, Panter SS, Desai TA, Lim DA. Radially branched deployment for more efficient cell transplantation at the scale of the human brain. Stereotact Funct Neurosurg. 2013; 91(2):92-103.
Ostrem JL, Galifianakis NB, Markun LC, Grace JK, Martin AJ, Starr PA, Larson PS. Clinical outcomes of PD patients having bilateral STN DBS using high-field interventional MR-imaging for lead placement. Clin Neurol Neurosurg. 2013 Jun; 115(6):708-12.
Rosenbluth KH, Martin AJ, Bringas J, Bankiewicz KS. Evaluation of pressure-driven brain infusions in nonhuman primates by intra-operative 7 Tesla MRI. J Magn Reson Imaging. 2012 Dec; 36(6):1339-46.
Hasan DM, Amans M, Tihan T, Hess C, Guo Y, Cha S, Su H, Martin AJ, Lawton MT, Neuwelt EA, Saloner DA, Young WL. Ferumoxytol-enhanced MRI to Image Inflammation within Human Brain Arteriovenous Malformations: A Pilot Investigation. Transl Stroke Res. 2012 Jul; 3(Suppl 1):166-73.
Larson PS, Starr PA, Bates G, Tansey L, Richardson RM, Martin AJ. An optimized system for interventional magnetic resonance imaging-guided stereotactic surgery: preliminary evaluation of targeting accuracy. Neurosurgery. 2012 Mar; 70(1 Suppl Operative):95-103; discussion 103.
Wenk JF, Klepach D, Lee LC, Zhang Z, Ge L, Tseng EE, Martin A, Kozerke S, Gorman JH, Gorman RC, Guccione JM. First evidence of depressed contractility in the border zone of a human myocardial infarction. Ann Thorac Surg. 2012 Apr; 93(4):1188-93.
Hasan DM, Mahaney KB, Magnotta VA, Kung DK, Lawton MT, Hashimoto T, Winn HR, Saloner D, Martin A, Gahramanov S, Dósa E, Neuwelt E, Young WL. Macrophage imaging within human cerebral aneurysms wall using ferumoxytol-enhanced MRI: a pilot study. Arterioscler Thromb Vasc Biol. 2012 Apr; 32(4):1032-8.
Ordovas KG, Carlsson M, Lease KE, Foster E, Meadows AK, Martin AJ, Hope M, Do L, Higgins CB, Saeed M. Impaired regional left ventricular strain after repair of tetralogy of Fallot. J Magn Reson Imaging. 2012 Jan; 35(1):79-85.
Richardson RM, Kells AP, Martin AJ, Larson PS, Starr PA, Piferi PG, Bates G, Tansey L, Rosenbluth KH, Bringas JR, Berger MS, Bankiewicz KS. Novel platform for MRI-guided convection-enhanced delivery of therapeutics: preclinical validation in nonhuman primate brain. Stereotact Funct Neurosurg. 2011; 89(3):141-51.
Carlsson M, Jablonowski R, Martin AJ, Ursell PC, Saeed M. Coronary microembolization causes long-term detrimental effects on regional left ventricular function. Scand Cardiovasc J. 2011 Aug; 45(4):205-14.
Boussel L, Rayz V, Martin A, Lawton M, Higashida R, Smith WS, Young WL, Saloner D. Temporal stability of dysmorphic fusiform aneurysms of the intracranial internal carotid artery. J Vasc Interv Radiol. 2011 Jul; 22(7):1007-11.
Richardson RM, Kells AP, Rosenbluth KH, Salegio EA, Fiandaca MS, Larson PS, Starr PA, Martin AJ, Lonser RR, Federoff HJ, Forsayeth JR, Bankiewicz KS. Interventional MRI-guided putaminal delivery of AAV2-GDNF for a planned clinical trial in Parkinson's disease. Mol Ther. 2011 Jun; 19(6):1048-57.
Saeed M, Martin AJ, Saloner D, Do L, Wilson M. Noninvasive MR characterization of structural and functional components of reperfused infarct. Acta Radiol. 2010 Dec; 51(10):1093-102.
Settecase F, Hetts SW, Martin AJ, Roberts TP, Bernhardt AF, Evans L, Malba V, Saeed M, Arenson RL, Kucharzyk W, Wilson MW. RF Heating of MRI-Assisted Catheter Steering Coils for Interventional MRI. Acad Radiol. 2011 Mar; 18(3):277-85.
Bernhardt A, Wilson MW, Settecase F, Evans L, Malba V, Martin AJ, Saeed M, Roberts TP, Arenson RL, Hetts SW. Steerable catheter microcoils for interventional MRI reducing resistive heating. Acad Radiol. 2011 Mar; 18(3):270-6.
Saeed M, Saloner D, Do L, Wilson M, Martin A. Cardiovascular magnetic resonance imaging in delivering and evaluating the efficacy of hepatocyte growth factor gene in chronic infarct scar. Cardiovasc Revasc Med. 2011 Mar-Apr; 12(2):111-22.
Saloner D, Uzelac A, Hetts S, Martin A, Dillon W. Modern meningioma imaging techniques. J Neurooncol. 2010 Sep; 99(3):333-40.
Carlsson M, Saloner D, Martin AJ, Ursell PC, Saeed M. Heterogeneous microinfarcts caused by coronary microemboli: evaluation with multidetector CT and MR imaging in a swine model. Radiology. 2010 Mar; 254(3):718-28.
Starr PA, Martin AJ, Ostrem JL, Talke P, Levesque N, Larson PS. Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracy. J Neurosurg. 2010 Mar; 112(3):479-90.
Dicks DL, Carlsson M, Heiberg E, Martin A, Saloner D, Arheden H, Saeed M. Persistent decline in longitudinal and radial strain after coronary microembolization detected on velocity encoded phase contrast magnetic resonance imaging. J Magn Reson Imaging. 2009 Jul; 30(1):69-76.
Dicks D, Saloner D, Martin A, Carlsson M, Saeed M. Percutaneous transendocardial VEGF gene therapy: MRI guided delivery and characterization of 3D myocardial strain. Int J Cardiol. 2010 Sep 03; 143(3):255-63.
Starr PA, Martin AJ, Larson PS. Implantation of deep brain stimulator electrodes using interventional MRI. Neurosurg Clin N Am. 2009 Apr; 20(2):193-203.
Martin AJ, Starr PA, Larson PS. Software requirements for interventional MR in restorative and functional neurosurgery. Neurosurg Clin N Am. 2009 Apr; 20(2):179-86.
Carlsson M, Martin AJ, Ursell PC, Saloner D, Saeed M. Magnetic resonance imaging quantification of left ventricular dysfunction following coronary microembolization. Magn Reson Med. 2009 Mar; 61(3):595-602.
Boussel L, Rayz V, Martin A, Acevedo-Bolton G, Lawton MT, Higashida R, Smith WS, Young WL, Saloner D. Phase-contrast magnetic resonance imaging measurements in intracranial aneurysms in vivo of flow patterns, velocity fields, and wall shear stress: comparison with computational fluid dynamics. Magn Reson Med. 2009 Feb; 61(2):409-17.
Carlsson M, Wilson M, Martin AJ, Saeed M. Myocardial microinfarction after coronary microembolization in swine: MR imaging characterization. Radiology. 2009 Mar; 250(3):703-13.
Martin AJ, Larson PS, Ostrem JL, Starr PA. Interventional magnetic resonance guidance of deep brain stimulator implantation for Parkinson disease. Top Magn Reson Imaging. 2009 Jan; 19(4):213-21.
Martin AJ, Baek B, Acevedo-Bolton G, Higashida RT, Comstock J, Saloner DA. MR imaging during endovascular procedures: an evaluation of the potential for catheter heating. Magn Reson Med. 2009 Jan; 61(1):45-53.
Rayz VL, Boussel L, Acevedo-Bolton G, Martin AJ, Young WL, Lawton MT, Higashida R, Saloner D. Numerical simulations of flow in cerebral aneurysms: comparison of CFD results and in vivo MRI measurements. J Biomech Eng. 2008 Oct; 130(5):051011.
Saeed M, Martin A, Jacquier A, Bucknor M, Saloner D, Do L, Ursell P, Su H, Kan YW, Higgins CB. Permanent coronary artery occlusion: cardiovascular MR imaging is platform for percutaneous transendocardial delivery and assessment of gene therapy in canine model. Radiology. 2008 Nov; 249(2):560-71.
Boussel L, Rayz V, McCulloch C, Martin A, Acevedo-Bolton G, Lawton M, Higashida R, Smith WS, Young WL, Saloner D. Aneurysm growth occurs at region of low wall shear stress: patient-specific correlation of hemodynamics and growth in a longitudinal study. Stroke. 2008 Nov; 39(11):2997-3002.
Saeed M, Martin A, Ursell P, Do L, Bucknor M, Higgins CB, Saloner D. MR assessment of myocardial perfusion, viability, and function after intramyocardial transfer of VM202, a new plasmid human hepatocyte growth factor in ischemic swine myocardium. Radiology. 2008 Oct; 249(1):107-18.
Taouli B, Chouli M, Martin AJ, Qayyum A, Coakley FV, Vilgrain V. Chronic hepatitis: role of diffusion-weighted imaging and diffusion tensor imaging for the diagnosis of liver fibrosis and inflammation. J Magn Reson Imaging. 2008 Jul; 28(1):89-95.
Carlsson M, Osman NF, Ursell PC, Martin AJ, Saeed M. Quantitative MR measurements of regional and global left ventricular function and strain after intramyocardial transfer of VM202 into infarcted swine myocardium. Am J Physiol Heart Circ Physiol. 2008 Aug; 295(2):H522-32.
Martin AJ, Hall WA, Roark C, Starr PA, Larson PS, Truwit CL. Minimally invasive precision brain access using prospective stereotaxy and a trajectory guide. J Magn Reson Imaging. 2008 Apr; 27(4):737-43.
Rayz VL, Lawton MT, Martin AJ, Young WL, Saloner D. Numerical simulation of pre- and postsurgical flow in a giant basilar aneurysm. J Biomech Eng. 2008 Apr; 130(2):021004.
Hushek SG, Martin AJ, Steckner M, Bosak E, Debbins J, Kucharzyk W. MR systems for MRI-guided interventions. J Magn Reson Imaging. 2008 Feb; 27(2):253-66.
Larson PS, Richardson RM, Starr PA, Martin AJ. Magnetic resonance imaging of implanted deep brain stimulators: experience in a large series. Stereotact Funct Neurosurg. 2008; 86(2):92-100.
Boussel L, Wintermark M, Martin A, Dispensa B, VanTijen R, Leach J, Rayz V, Acevedo-Bolton G, Lawton M, Higashida R, Smith WS, Young WL, Saloner D. Monitoring serial change in the lumen and outer wall of vertebrobasilar aneurysms. AJNR Am J Neuroradiol. 2008 Feb; 29(2):259-64.
Jacquier A, Higgins CB, Martin AJ, Do L, Saloner D, Saeed M. Injection of adeno-associated viral vector encoding vascular endothelial growth factor gene in infarcted swine myocardium: MR measurements of left ventricular function and strain. Radiology. 2007 Oct; 245(1):196-205.
Dispensa BP, Saloner DA, Acevedo-Bolton G, Achrol AS, Jou LD, McCulloch CE, Johnston SC, Higashida RT, Dowd CF, Halbach VV, Ko NU, Lawton MT, Martin AJ, Quinnine N, Young WL. Estimation of fusiform intracranial aneurysm growth by serial magnetic resonance imaging. J Magn Reson Imaging. 2007 Jul; 26(1):177-83.
Akhtar M, Ordovas K, Martin A, Higgins CB, Michaels AD. Effect of chronic sustained-release dipyridamole on myocardial blood flow and left ventricular function in patients with ischemic cardiomyopathy. Congest Heart Fail. 2007 May-Jun; 13(3):130-5.
Saeed M, Saloner D, Martin A, Do L, Weber O, Ursell PC, Jacquier A, Lee R, Higgins CB. Adeno-associated viral vector-encoding vascular endothelial growth factor gene: effect on cardiovascular MR perfusion and infarct resorption measurements in swine. Radiology. 2007 May; 243(2):451-60.
Saeed M, Weber O, Lee R, Do L, Martin A, Saloner D, Ursell P, Robert P, Corot C, Higgins CB. Discrimination of myocardial acute and chronic (scar) infarctions on delayed contrast enhanced magnetic resonance imaging with intravascular magnetic resonance contrast media. J Am Coll Cardiol. 2006 Nov 21; 48(10):1961-8.
Saeed M, Henk CB, Weber O, Martin A, Wilson M, Shunk K, Saloner D, Higgins CB. Delivery and assessment of endovascular stents to repair aortic coarctation using MR and X-ray imaging. J Magn Reson Imaging. 2006 Aug; 24(2):371-8.
Acevedo-Bolton G, Jou LD, Dispensa BP, Lawton MT, Higashida RT, Martin AJ, Young WL, Saloner D. Estimating the hemodynamic impact of interventional treatments of aneurysms: numerical simulation with experimental validation: technical case report. Neurosurgery. 2006 Aug; 59(2):E429-30; author reply E429-30.
Saeed M, Martin AJ, Lee RJ, Weber O, Revel D, Saloner D, Higgins CB. MR guidance of targeted injections into border and core of scarred myocardium in pigs. Radiology. 2006 Aug; 240(2):419-26.
Saeed M, Lee RJ, Weber O, Do L, Martin A, Ursell P, Saloner D, Higgins CB. Scarred myocardium imposes additional burden on remote viable myocardium despite a reduction in the extent of area with late contrast MR enhancement. Eur Radiol. 2006 Apr; 16(4):827-36.
Martin AJ, Larson PS, Ostrem JL, Keith Sootsman W, Talke P, Weber OM, Levesque N, Myers J, Starr PA. Placement of deep brain stimulator electrodes using real-time high-field interventional magnetic resonance imaging. Magn Reson Med. 2005 Nov; 54(5):1107-14.
Zaharchuk G, Martin AJ, Rosenthal G, Manley GT, Dillon WP. Measurement of cerebrospinal fluid oxygen partial pressure in humans using MRI. Magn Reson Med. 2005 Jul; 54(1):113-21.
Schalla S, Saeed M, Higgins CB, Weber O, Martin A, Moore P. Balloon sizing and transcatheter closure of acute atrial septal defects guided by magnetic resonance fluoroscopy: assessment and validation in a large animal model. J Magn Reson Imaging. 2005 Mar; 21(3):204-11.
Martin AJ, Saloner DA, Roberts TP, Roberts H, Weber OM, Dillon W, Cullen S, Halbach V, Dowd CF, Higashida RT. Carotid stent delivery in an XMR suite: immediate assessment of the physiologic impact of extracranial revascularization. AJNR Am J Neuroradiol. 2005 Mar; 26(3):531-7.
Ko NU, Achrol AS, Martin AJ, Chopra M, Saloner DA, Higashida RT, Young WL. Magnetic resonance perfusion tracks 133Xe cerebral blood flow changes after carotid stenting. Stroke. 2005 Mar; 36(3):676-8.
Saeed M, Saloner D, Weber O, Martin A, Henk C, Higgins C. MRI in guiding and assessing intramyocardial therapy. Eur Radiol. 2005 May; 15(5):851-63.
Weber OM, Pujadas S, Martin AJ, Higgins CB. Free-breathing, three-dimensional coronary artery magnetic resonance angiography: comparison of sequences. J Magn Reson Imaging. 2004 Sep; 20(3):395-402.
Taouli B, Martin AJ, Qayyum A, Merriman RB, Vigneron D, Yeh BM, Coakley FV. Parallel imaging and diffusion tensor imaging for diffusion-weighted MRI of the liver: preliminary experience in healthy volunteers. AJR Am J Roentgenol. 2004 Sep; 183(3):677-80.
Saeed M, Lee R, Martin A, Weber O, Krombach GA, Schalla S, Lee M, Saloner D, Higgins CB. Transendocardial delivery of extracellular myocardial markers by using combination X-ray/MR fluoroscopic guidance: feasibility study in dogs. Radiology. 2004 Jun; 231(3):689-96.
Weber OM, Martin AJ, Higgins CB. Whole-heart steady-state free precession coronary artery magnetic resonance angiography. Magn Reson Med. 2003 Dec; 50(6):1223-8.
Jou LD, Quick CM, Young WL, Lawton MT, Higashida R, Martin A, Saloner D. Computational approach to quantifying hemodynamic forces in giant cerebral aneurysms. AJNR Am J Neuroradiol. 2003 Oct; 24(9):1804-10.
Weber OM, Schalla S, Martin AJ, Saeed M, Lee R, Shunk KA, Moore P, Higgins CB. Interventional cardiac magnetic resonance imaging. Semin Roentgenol. 2003 Oct; 38(4):352-7.
Schalla S, Saeed M, Higgins CB, Martin A, Weber O, Moore P. Magnetic resonance--guided cardiac catheterization in a swine model of atrial septal defect. Circulation. 2003 Oct 14; 108(15):1865-70.
Wilson MW, Fidelman N, Weber OM, Martin AJ, Gordon RL, LaBerge JM, Kerlan RK, Wolanske KA, Saeed M. Experimental renal artery embolization in a combined MR imaging/angiographic unit. J Vasc Interv Radiol. 2003 Sep; 14(9 Pt 1):1169-75.
Martin AJ, Weber OM, Saeed M, Roberts TP. Steady-state imaging for visualization of endovascular interventions. Magn Reson Med. 2003 Aug; 50(2):434-8.
Kuehne T, Saeed M, Higgins CB, Gleason K, Krombach GA, Weber OM, Martin AJ, Turner D, Teitel D, Moore P. Endovascular stents in pulmonary valve and artery in swine: feasibility study of MR imaging-guided deployment and postinterventional assessment. Radiology. 2003 Feb; 226(2):475-81.
Wilson MW, LaBerge JM, Kerlan RK, Martin AJ, Weber OM, Roberts T, Vitalich C, Higgins CB, Gordon RL. MR portal venography: preliminary results of fast acquisition without contrast material or breath holding. Acad Radiol. 2002 Oct; 9(10):1179-84.
Fidelman N, Wilson MW, Weber OM, Martin AJ, Kerlan RK, LaBerge JM, Gordon RL. Real-time MR properties of particulate embolic agents tested in a dynamic flow model. J Vasc Interv Radiol. 2002 Jun; 13(6):613-8.
Hall WA, Liu H, Martin AJ, Truwit CL. Minimally invasive procedures. Interventional MR image-guided neurobiopsy. Neuroimaging Clin N Am. 2001 Nov; 11(4):705-13.
Michel E, Liu H, Remley KB, Martin AJ, Madison MT, Kucharczyk J, Truwit CL. Perfusion MR neuroimaging in patients undergoing balloon test occlusion of the internal carotid artery. AJNR Am J Neuroradiol. 2001 Sep; 22(8):1590-6.
Liu H, Hall WA, Martin AJ, Truwit CL. An efficient chemical shift imaging scheme for magnetic resonance-guided neurosurgery. J Magn Reson Imaging. 2001 Jul; 14(1):1-7.
Martin AJ, Liu H, Hall WA, Truwit CL. Preliminary assessment of turbo spectroscopic imaging for targeting in brain biopsy. AJNR Am J Neuroradiol. 2001 May; 22(5):959-68.
Liu H, Hall WA, Martin AJ, Truwit CL. Biopsy needle tip artifact in MR-guided neurosurgery. J Magn Reson Imaging. 2001 Jan; 13(1):16-22.
Hall WA, Liu H, Martin AJ, Maxwell RE, Truwit CL. Brain biopsy sampling by using prospective stereotaxis and a trajectory guide. J Neurosurg. 2001 Jan; 94(1):67-71.
Liu H, Hall WA, Martin AJ, Maxwell RE, Truwit CL. MR-guided and MR-monitored neurosurgical procedures at 1.5 T. J Comput Assist Tomogr. 2000 Nov-Dec; 24(6):909-18.
Hall WA, Liu H, Martin AJ, Truwit CL. Intraoperative magnetic resonance imaging. Top Magn Reson Imaging. 2000 Jun; 11(3):203-12.
Martin AJ, Hall WA, Liu H, Pozza CH, Michel E, Casey SO, Maxwell RE, Truwit CL. Brain tumor resection: intraoperative monitoring with high-field-strength MR imaging-initial results. Radiology. 2000 Apr; 215(1):221-8.
Hall WA, Liu H, Martin AJ, Pozza CH, Maxwell RE, Truwit CL. Safety, efficacy, and functionality of high-field strength interventional magnetic resonance imaging for neurosurgery. Neurosurgery. 2000 Mar; 46(3):632-41; discussion 641-2.
Gordon MJ, Chu KC, Margaritis A, Martin AJ, Ethier CR, Rutt BK. Measurement of Gd-DTPA diffusion through PVA hydrogel using a novel magnetic resonance imaging method. Biotechnol Bioeng. 1999 Nov 20; 65(4):459-67.
Hall WA, Martin AJ, Liu H, Nussbaum ES, Maxwell RE, Truwit CL. Brain biopsy using high-field strength interventional magnetic resonance imaging. Neurosurgery. 1999 Apr; 44(4):807-13; discussion 813-4.
Hall WA, Liu H, Martin AJ, Truwit CL. Comparison of stereotactic brain biopsy to interventional magnetic-resonance-imaging-guided brain biopsy. Stereotact Funct Neurosurg. 1999; 73(1-4):148-53.
Hall WA, Martin AJ, Liu H, Pozza CH, Casey SO, Michel E, Nussbaum ES, Maxwell RE, Truwit CL. High-field strength interventional magnetic resonance imaging for pediatric neurosurgery. Pediatr Neurosurg. 1998 Nov; 29(5):253-9.
Martin AJ, McLoughlin RF, Chu KC, Barberi EA, Rutt BK. An expandable intravenous RF coil for arterial wall imaging. J Magn Reson Imaging. 1998 Jan-Feb; 8(1):226-34.
Liu H, Martin AJ, Truwit CL. Interventional MRI at high-field (1.5 T): needle artifacts. J Magn Reson Imaging. 1998 Jan-Feb; 8(1):214-9.
Chu KC, Martin AJ, Rutt BK. Improved MR images of arterial specimens by submersion in trichlorotrifluoroethane. Magn Reson Med. 1996 May; 35(5):790-6.
Martin AJ, Henkelman RM. Intravascular MR imaging in a porcine animal model. Magn Reson Med. 1994 Aug; 32(2):224-9.
Martin AJ, Plewes DB, Henkelman RM. MR imaging of blood vessels with an intravascular coil. J Magn Reson Imaging. 1992 Jul-Aug; 2(4):421-9.
Martin AJ, Drake JM, Lemaire C, Henkelman RM. Cerebrospinal fluid shunts: flow measurements with MR imaging. Radiology. 1989 Oct; 173(1):243-7.